24/7 Emergency HVAC Available
(647) 280-6626
Immediate Emergency Safety Rule

If you suspect a natural gas leak, leave the building immediately.

Do not operate electrical switches, do not use phones indoors, do not investigate the source, and do not wait for an HVAC appointment. From a safe outdoor location, call 911 or the Enbridge Gas 24/7 emergency hotline at 1-866-763-5427. Do not re-enter until emergency personnel declare the building safe.

Licensed TSSA Gas Fitter · Diagnostic & Safety Testing

Gas Leak Detection in Mississauga

Real Deal HVAC provides professional gas line testing, red-tag remediation, and post-incident piping repair. All work is performed directly by licensed TSSA gas fitters using calibrated electronic detectors and static pressure gauge tests.

When to use this page and form:

This booking form is for non-emergency preventative inspections, clearing an Enbridge red tag after gas has been safely isolated, or scheduling diagnostic checks on newly renovated piping. Never use this form during an active emergency.

TSSA Certified
Licensed gas fitters
Pressure Gauge
Certified testing
★ 5.0 on Google
181 verified reviews
Written Quote
Prior to any repair
RD Website — Service Request24/7 Monitored

Book a Gas Line Inspection

Staff confirm appointment availability. For an active gas smell, evacuate and call Enbridge from outside.

Staff review and confirm your exact window. Price agreed in writing before any work begins.

Life-Safety Protocol

Suspected Gas Leak Safety Rules

Do not attempt to evaluate the severity of the leak or delay evacuation. Every uncontrolled release of natural gas carries an explosion and fire hazard. Follow these non-negotiable steps:

1

Evacuate Immediately

Get every person and pet outside immediately. Leave doors as you exit, but do not linger to open windows or gather belongings.

2

Avoid Any Spark Source

Do NOT touch light switches, garage door openers, landlines, or cell phones indoors. Do NOT start a vehicle parked near the home or inside a garage.

3

Call from Outside

From a safe distance, call the Enbridge 24/7 emergency response line at 1-866-763-5427 or dial 911. Do not re-enter under any circumstances until officially cleared.

Technical Diagnostics

How Qualified Technicians Detect & Pinpoint Gas Leaks

These procedures require specialized instrumentation, certified pressure gauges, and a TSSA fuel license. They are performed exclusively by our qualified professionals once premises are safe:

1

Initial Safety Verification

Our technician confirms the structure has been declared safe to enter by utility or emergency personnel before performing diagnostics. If an active hazardous atmosphere exists, work pauses immediately.

2

Handheld Electronic Gas Sniffer

A calibrated combustible gas detector senses minute concentrations of methane along exposed pipe runs, shut-off valves, and appliance unions where human smell cannot localize the source.

3

Certified Bubble Solution Testing

A non-corrosive, freeze-protected leak detection fluid is applied to every threaded fitting, union, and valve stem to visually confirm escaping gas via micro-bubbling.

4

Manifold Pressure Gauge Testing

The gas line is isolated and pressurized on a calibrated test gauge. Any pressure drop proves escaping gas along the run, including concealed segments behind ceilings or framing.

5

Burner & Appliance Safety Inspection

We verify appliance gas valves, regulators, and burners for proper lockup pressure and clean combustion once piping integrity is fully confirmed.

6

Permanent Repair & Re-Testing

Repairs use code-compliant black iron fittings, CSA-approved valves, or certified connectors. The entire system is re-pressurized to confirm 100% gas tightness before reopening supply.

Clean blue flames on a gas burner inside a properly maintained heating system
Proper fuel-air ratio produces stable blue flames. Incomplete combustion produces toxic carbon monoxide (CO), which is invisible and odorless.
Critical Safety Distinction

Carbon Monoxide Alarms vs Natural Gas Leaks

Both are serious heating emergencies, but they are caused by different gases and require different responses:

If your Carbon Monoxide (CO) alarm sounds:

Leave the building immediately and call 911 from outside. CO has no smell, taste, or color. It is produced by incomplete combustion in a cracked heat exchanger, blocked chimney, or venting failure. Do not stay to ventilate the home; evacuate first.

If you smell Natural Gas (rotten eggs):

Leave the building immediately. Natural gas is naturally odorless, but the utility adds mercaptan so leaks can be detected. Call Enbridge at 1-866-763-5427 or call 911 from a safe outdoor location.

Emergency Routing

Who to Call During a Gas Event

Safety first: emergency responders isolate and secure. Real Deal HVAC repairs private piping and clears tags once the premises are cleared.

SituationPrimary ContactRequired Immediate Action
Any suspected natural gas leakEnbridge Gas (1-866-763-5427) or 911Evacuate building immediately; call from outside
Carbon monoxide (CO) alarm sounding911Evacuate building immediately; call 911 from outside
Gas leak outside near utility meterEnbridge Gas (1-866-763-5427)Keep clear of the meter; call from safe distance
Enbridge red tag issued / pipe repair neededReal Deal HVAC ((647) 280-6626)Book certified TSSA repair once emergency is stabilized
Preventative line check for home purchase / renoReal Deal HVAC ((647) 280-6626)Schedule a non-emergency pressure gauge test
FAQ

Gas Safety & Leak Testing FAQs

What should I do if I suspect a natural gas leak in my home?

Leave the area or building immediately. Do not use any light switches, telephones, or appliances inside, and do not investigate the source. Once in a safe outdoor location, call 911 or the Enbridge Gas 24/7 emergency line at 1-866-763-5427. Do not re-enter until emergency personnel confirm the premises are safe.

Can I wait to see if a faint gas smell goes away?

No. Never rely on the intensity of a smell to decide whether to evacuate. Any suspected gas leak must be treated as an immediate life-safety hazard: evacuate everyone outside first and contact Enbridge or 911 from safety. Routine booking with Real Deal HVAC is only for non-emergency preventative inspections or repair after responders have made the premises safe.

What should I do if my carbon monoxide (CO) alarm sounds?

Leave the home immediately, taking all family members and pets outside into fresh air. From safety, call 911 immediately. Never stay inside to open windows or investigate heating equipment while an alarm is sounding. Do not re-enter until the fire department or emergency responders clear the building.

Will Enbridge Gas repair my leaking indoor pipes?

No. Enbridge emergency crews respond to make the situation safe—they will locate the immediate hazard, shut off the gas supply, and issue a red tag if private piping or equipment is non-compliant. They do not repair private residential piping. You must hire a licensed TSSA gas contractor such as Real Deal HVAC to complete the repairs and clear the tag.

Can a homeowner check for gas leaks using DIY methods?

Never use an open flame, lighter, match, or electrical device to search for gas leaks. Homeowners should never attempt gas diagnostic procedures or disassembly. Gas piping in Ontario is governed by CSA B149.1 safety codes and requires licensed TSSA technicians with specialized test gauges and certified sniffers.

Can a carbon monoxide detector detect natural gas?

No. Carbon monoxide detectors measure CO gas, which is a poisonous, odorless byproduct of incomplete combustion. They do not detect unburned natural gas (methane). Natural gas has a rotten-egg chemical odorant (mercaptan) added by the utility. Dedicated natural gas detectors can be installed separately.

How does a licensed technician find a leak hidden behind a wall?

A licensed gas fitter isolates the line and performs a static pressure gauge test. If the gauge needle drops over time, gas is escaping somewhere on that run. Individual appliance branch valves are isolated systematically to determine the exact pipe section without opening unnecessary drywall.

What happens after I request a gas inspection through this form?

Our dispatch staff reviews your request and calls or messages to confirm an appointment. This form does not auto-schedule and is NOT monitored for real-time life-safety emergencies. If you currently smell gas or suspect an active leak, evacuate and call 1-866-763-5427 or 911 immediately.